Genuine BFT Automation Products UAE.
WhatsApp Call

PD-132 Vehicle Loop Detector 24V UAE

Original BFT Product
UAE Wide Delivery
Technical Support
99.00 AED
In Stock
Order on WhatsApp
Specification

PD-132 Vehicle Loop Detector 24V UAE

PD-132 Vehicle Loop Detector 24V – Product Introduction

PD-132 Vehicle Loop Detector 24V provides one channel for monitoring an induction loop at a controlled vehicle entrance. A loop laid in the driveway responds to the metal mass of a vehicle; the detector converts that change into an output that a compatible gate, barrier or access-control controller can use. This makes it a useful accessory when an installation needs vehicle presence information rather than a handheld command alone.

The PD-132 24V is intended for integration into a complete automation installation. This version requires 24V AC/DC. Its single-loop arrangement suits a defined detection position such as an exit approach or a monitored area at a parking entrance.

For UAE villas, residential compounds, commercial car parks and industrial entrances, correct detector selection starts with the control-board input, available power supply and required operating sequence. A detector does not independently decide how a gate or barrier moves: the connected controller and its settings determine the resulting action.

Key Features

  • Single channel inductive vehicle loop detector
  • Model: PD-132 24V
  • 24V AC/DC power supply
  • Suitable for parking barriers and automatic gates
  • Fast 10ms detection response
  • 4 adjustable sensitivity levels
  • Frequency range: 20kHz to 170kHz
  • Presence detection relay output
  • Unlimited or 10-minute presence holding mode
  • Loop inductance range: 50μH to 1000μH
  • Recommended loop inductance: 100μH to 300μH
  • Maximum loop feeder length: 20 metres
  • Compact industrial housing
  • Suitable for professional gate and parking installations

Technical Specifications

  • Model: PD-132 24V
  • Product Type: Vehicle Loop Detector
  • Detection Technology: Inductive Loop Vehicle Detection
  • Channels: Single Channel
  • Supply Voltage: 24V AC/DC
  • Power Consumption: 4.5VA
  • Output Relay Rating: 240V / 5A
  • Frequency Range: 20kHz – 170kHz
  • Reaction Time: 10ms
  • Sensitivity: 4 Adjustable Levels
  • Loop Inductance Range: 50μH – 1000μH
  • Recommended Loop Inductance: 100μH – 300μH
  • Maximum Loop Feeder Length: 20 Metres
  • Presence Time: Unlimited / 10 Minutes Limited
  • Operating Temperature: -20°C to +65°C
  • Storage Temperature: -40°C to +85°C
  • Housing Dimensions: 78 × 40 × 108 mm

How Inductive Vehicle Detection Works

The cable loop and detector work together as a sensing circuit. When a vehicle enters the loop area, its metal mass changes the loop inductance. The detector recognises the change and switches its output according to the selected mode. The loop position therefore defines the area being monitored.

Choose the detection position to suit the required operation. An approach loop can request opening, while a presence loop can report that a vehicle remains in a monitored area. These functions depend on a compatible controller, correct wiring and tested system logic.

Sensitivity, Frequency and Response

The PD-132 24V provides four sensitivity settings and a stated response time of 10 ms. The operating frequency range is 20–170 kHz. Frequency selection lets the installer adjust operation where neighbouring loops could interfere with each other.

Sensitivity should be selected for the actual loop geometry, vehicles and site conditions. Commissioning should include testing the vehicles expected to use the entrance, both while moving over the loop and while stopped within it.

Presence and Output Configuration

A presence output reports detection while a vehicle occupies the loop. A pulse function, where configured, supplies a brief event signal. Select the mode to suit the receiving controller rather than treating the two as interchangeable. The supported presence choices include unlimited holding or a limited 10-minute mode.

The relay rating describes the output contact capacity; it does not identify the detector supply voltage. Verify the terminal diagram and the receiving input before wiring. The detector is an automation input device and is not a replacement for the motor controller.

Loop Cable and Installation Planning

A total loop inductance of 100–300 μH is recommended. The supported range is 50–1000 μH. The stated maximum loop connection or feeder length is 20 m. Plan cable routing, turns and loop dimensions to remain within the exact detector requirements.

Correct cable insulation, secure terminations, feeder twisting and a properly sealed road loop are essential to stable detection. For the 12 V and 24 V PD-132 reference versions, the feeder guidance specifies at least 20 twists per metre. Test the completed loop and detector before returning the entrance to normal operation.

Gate, Barrier and Access-Control Integration

Suitable applications include compatible parking barriers, sliding gates, swing gates, RFID access systems, residential entrances, commercial car parks, warehouses and factories. Opening, free-exit, presence or protective functions are available only where the connected controller supports the intended input and operating logic.

Have the complete installation assessed and tested, including existing safety devices. Inductive vehicle sensing should not be treated as comprehensive pedestrian detection. Keep the detector in a suitable installation enclosure and follow the exact product instructions for electrical connection and environmental limits.

Package and Ordering Information

The listing covers the detector. Confirm the socket/base where not expressly included, road-loop cable, sealant, enclosure and installation work when ordering. A gate motor, barrier or road-cutting service is not automatically included in the detector price.

Supply and Installation Support in the UAE

BFT Automation UAE can assist with product selection and enquiries for Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah, Fujairah, Umm Al Quwain and Al Ain. Send the existing equipment model and installation details so compatibility and any additional parts can be checked.

Request a quotation for delivery, fitting, wiring and commissioning as applicable. Service scope, availability and warranty terms should be confirmed for your order; accessory supply alone does not automatically include installation.

Frequently Asked Questions

How many loops does this model monitor?

One inductive loop.

Which power supply does it require?

24V AC/DC. Confirm the unit label and wiring diagram before installation.

Can it open a gate automatically?

It can provide a detection signal to a compatible opening input. The gate controller, wiring and configuration determine the response.

Is the road-loop cable included?

Cable is a separate installation requirement unless your quotation explicitly includes it.

Does it work with every gate controller?

Compatibility must be checked against the controller input, output mode and electrical requirements.

Order or Ask a Product Question

Call / WhatsApp: +971525223840
Email: sales@bftautomationuae.com

Tags: PD-132 24V, gate automation accessories, UAE